DSpace Repository

Measurements of Neutrons In A Mixed GammaNeutron Field Using Three Different Types of Detectors

Show simple item record

dc.contributor.author Leal, B.
dc.contributor.author Castillo, F.
dc.contributor.author Gutierrez, J.
dc.contributor.author Golzarri, J. I
dc.contributor.author Gamboa-Debuen, I.
dc.contributor.author Espinosa, G.
dc.contributor.author Martinez, H.
dc.date.accessioned 2022-04-07T10:39:10Z
dc.date.available 2022-04-07T10:39:10Z
dc.date.issued 2017-08-07
dc.identifier.issn 2321-8649
dc.identifier.issn 2321-9289
dc.identifier.uri http://dspace.chitkarauniversity.edu.in/xmlui/handle/123456789/357
dc.description.abstract A linear electron accelerator for medical use is a device for the treatment of tumors by collimated beams of electrons and/or photons. These accelerators are devices that employ electromagnetic waves of high frequency, to accelerate electrons that are used directly in the treatment of superficial tumors, or, if they are made to hit them on an appropriate target, they can produce photons of high energy destined to the treatment of deeptumors.Depending on the energy of the electrons and photons and the materials that make up the head of the accelerator and the target, this equipment will produce in addition to the aforementioned radiation, neutron fields of regular intensity. It is necessary to estimate the equivalent dose due to the neutrons themselves, the doses due to the gamma field of neutron capture, produced by the capture of thermal neutrons in the concrete of the bunker, and the gamma doses due to phenomena of neutron activation of elements of the own accelerator. It is therefore important to be able to measure (detect, quantify, dose, etc.) both photons and neutrons in these cases and others more. In this work we use three different detectors, namely a scintillator-photomultiplier system, a fast reading dosimeter and bubble detector. The idea is to measure the radiation separately and compare their results. The results obtained were the mixed gamma-neutron field spectrum, the dose due only to neutrons obtained by the bubble detectors, which is compared to the dose obtained by the second fast reading dosimeters (model 884), plus the dose obtained by the first dosimeters (model 609) and finally the dose obtained by the Victoreen dosimeter. en_US
dc.language.iso en en_US
dc.relation.ispartofseries ;CHAENG/2013/51628
dc.subject Detectors en_US
dc.subject Gammas en_US
dc.subject Neutrons en_US
dc.subject Dosimeters en_US
dc.title Measurements of Neutrons In A Mixed GammaNeutron Field Using Three Different Types of Detectors en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account