Please use this identifier to cite or link to this item: http://dspace.chitkarauniversity.edu.in/xmlui/handle/123456789/184
Title: Study through Geant4, for Time Resolution characterization of different detectors arrays coupled with two SiPMs, as a function of: the scintillator plastic material, its volumetric dimensions and the location of the radiation emission source
Authors: Fernández, C. H. Zepeda
Efrén, Hernández Aguilar Javier
Moreno-Barbosa, E.
Keywords: Physics
Radiation Physics
SiPM
Simulation
Time resolution
Plastic scintillator
Issue Date: 10-Feb-2021
Publisher: Chitkara University Publications
Series/Report no.: ;CHAENG/2013/51628
Abstract: The high time resolution detectors are relevant in those experiments or simulations were the particles to detect, have a very short time of flight (TOF), and due this it´s required that the detections times are ranged between ns. & ps. Using Geant4 software, it was made thirty simulations of coupled detectors to plastic scintillators with two silicon photomultipliers (SiPMs) located on the scintillator’s central sides. To characterize the time resolution, it was required to quantify the optical photons that reach the Score in a certain time, which are generated by muons on the surface of the plastic scintillator. Different configurations of muon beams were simulated at energy of 1 GeV, to interact with the configuration of the scintillator material of its corresponding arrangement. The simulations were made varying three parameters: the scintillator material “BC404 & BC422”, its size, and the location of the radiation source. Fifteen simulations correspond to BC404 material & fifteen simulations to BC422 material respectively. The first five simulations consisted in varying the scintillator’s volumetric size and collocate the muons beam guided randomly distributed over it, the next five simulations differentiate from setting up a directly centered beam, and the last five simulations for guide the beam on the left lower corner of each scintillator. The best time resolution achieved was σ= 8.67 +/− 0.26 ps., reported by the detector with BC422 scintillator material which has a volume of 20x20x3 mm3.
URI: http://dspace.chitkarauniversity.edu.in/xmlui/handle/123456789/184
ISSN: 2321-8649
2321-9289
Appears in Collections:Vol. 8 No. 2 (2021)

Files in This Item:
File Description SizeFormat 
256-Article Text-760-1-10-20210209.pdf1.3 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.